Updated Feb 28, 2022 Test Engine to Practice Test for DES-1D12 Valid and Updated Dumps
Exam Questions for DES-1D12 Updated Versions With Test Engine
For more info visit:
How to book the DES-1D12 Exam
These are following steps for registering the Dell DES-1D12 exam.
- Step 1: Visit to Dell Exam Registration
- Step 2: Signup/Login
- Step 3: Search for Dell DES-1D12 Exam Certifications Exam
- Step 4: Select Date, time and confirm with payment method
Understanding functional and technical aspects of Storage Networking Technologies
The following will be discussed in DES-1D12 exam dumps pdf:
- Explain the components of block-based storage system, storage provisioning, and storage tiering mechanisms
- Explain the components and connectivities of FCIP and FCoE Storage Systems (26-
- Describe SC Series cross-platform replication functionality and use cases
- Explain the components of an intelligent storage system, RAID, erasure coding, data access methods, scale-up and scale-out architectures
- Identify key features of the SC Series operating system
- Describe PowerStore HA features, non-disruptive upgrades and migration options requirements and use cases
- Describe Unity Data Protection (e.g., Snapshots, Replication, and Snapshot Replication architectur- solutions and use cases
- Describe object-based storage device components, functions, operations, and unified storage architecture
- Describe Storage Area Network (SAN, FC architecture, FC topologies, zoning, and virtualization in FC SAN
- Describe software-defined storage attributes, architecture, functions of the control plane, software-defined extensibility, and software-defined networking functionalities
- Describe PowerStore Data Protection and Data Security (e.g., Snapshots, Consistency Groups, Thin Clone- features and use cases
- Describe TCP/IP, IP SAN, iSCSI protocol, components, connectivity, addressing, discovery domains, and VLAN
- Describe PowerStore Data Services and how to provision and access storage via block, files, and VMware datastores
- Describe Unity Data Mobility features, requirements, and use cases
- Describe the PowerStore load and resource balancing capabilities and PowerStore replication capabilities
NEW QUESTION 30
Which Dell EMC Unity storage array models support NVMe?
- A. 380, 880, and 880F
- B. 680, 680F, 880, and 880F
- C. 680F, 880, and 880F only
- D. 380, 380F, and 480F
Answer: D
Explanation:
Reference:
https://www.delltechnologies.com/en-us/storage/unity.htm#scroll=off
NEW QUESTION 31
Match each Dell EMC Unity feature with its destination.
Answer:
Explanation:
Reference:
<https://www.delltechnologies.com/resources/en-us/asset/white-papers/products/storage/h15572- dell_emc_unity-nas_capabilities.pdf>
NEW QUESTION 32
What is a key feature of the Dell EMC Future-Proof Storage Loyalty Program for Dell EMC SC Series arrays?
- A. 4:1 Performance Guarantee
- B. 4 Year Satisfaction Guarantee
- C. 4:1 Reduction Guarantee
- D. 4:1 Efficiency Guarantee
Answer: D
Explanation:
Explanation/Reference: https://www.dell.com/pk/business/p/storage-sc-all-flash/pd
NEW QUESTION 33
How many hierarchical snapshots are supported by Dell EMC Unity?
- A. 10 levels deep for LUNs
10 levels deep for file systems - B. 16 levels deep for LUNs
8 levels deep for file systems - C. 32 levels deep for LUNs
16 levels deep for file systems - D. 16 levels deep for LUNs
16 levels deep for file systems
Answer: A
Explanation:
https://elabnavigator.emc.com/vault/pdf/EMC_Unity_ESSM.pdf (pag.22)
NEW QUESTION 34
A customer configures their Live Volume setup for synchronous replication with the High Availability option. They are designing a DR resiliency plan to ensure data integrity in the event of data corruption.
Which Dell EMC SC Series technology should you use?
- A. Live Volume with Non-Uniform Presentation
- B. Synchronous Replication with High Consistency
- C. Live Volume with Uniform Presentation
- D. Live Volume with Managed Replication
Answer: D
Explanation:
Reference:
https://downloads.dell.com/manuals/common/dell-emc-sc-series-sync-replication-live-volume.pdf (7)
NEW QUESTION 35
A customer asks you about the maximum load of their new Dell EMC SC Series array. Which term should you use in response?
- A. Latency
- B. MB
- C. IOPS
- D. CPU Cycles
Answer: C
Explanation:
Reference:
https://downloads.dell.com/manuals/common/sc-series-performance-availability-best-practices-dell-emc-4024-bp-sc_en-us.pdf
NEW QUESTION 36
What is a characteristic of single-tier Flash on Dell EMC SC Series arrays?
- A. Read only data is migrated to lower tiers when a snapshot is taken
- B. Supports either write-intensive or read-intensive SSDs in the same tier
- C. Supports both write-intensive and read-intensive SSDs in the same tier
- D. Snapshot data is kept on Tier1 in RAID 10 to optimize performance
Answer: B
NEW QUESTION 37
What is a consequence of using an 800 GB drive and five 400 GB drives in a Dell EMC Unity XT dynamic pool?
- A. Extents 9 - 14 are used to create a RAID Group
- B. Extents 9 - 14 are marked unavailable until more 800 GB drives are added
- C. Unisphere short strokes the 800 GB drive to 8 extents
- D. Extents 9 - 14 are marked unavailable and can never be recovered
Answer: B
NEW QUESTION 38
What is the Dell EMC best practice for sizing and designing a Dell EMC SC Series solution?
- A. Drive capacity should meet performance needs
- B. Size for capacity; Data Progression should always meet performance needs
- C. Size for performance first and capacity second
- D. Front-end ports required for performance should always meet capacity needs
Answer: A
NEW QUESTION 39
From which Dell EMC storage system can a Dell EMC PowerStore array natively import data?
- A. VNX
- B. VNX2
- C. VMAX
- D. PowerVault
Answer: B
Explanation:
Reference:
https://www.dell.com/support/manuals/en-my/powerstore-1000/pwrstr-import/importing-external- storage-to-powerstore-overview?guid=guid-6fef77c4-d4c9-49c6-8de2-efd67aa52ca5#:~:text=Importing% 20external%20storage%20to%20PowerStore%20is%20a%20migration%20solution%20that,Dell%20EMC% 20Unity%20Series
NEW QUESTION 40
What is a feature of Dell EMC Unity unified snapshots?
- A. Copy on First Access
- B. Delta set extension
- C. Copy on First Write
- D. Redirect on Write
Answer: D
Explanation:
Reference; https://www.delltechnologies.com/en-ba/collaterals/unauth/white-papers/products/storage/h15089- dell_emc_unity-snapshots_and_thin_clones.pdf (7)
NEW QUESTION 41
A Dell EMC Unity storage administrator needs to build a NAS server configuration to support failover between SPs and NAS resources. What is a term for this configuration?
- A. IP Multi-tenancy
- B. Local Replication
- C. Separate IP Switches
- D. LACP
Answer: B
Explanation:
Explanation/Reference: https://www.delltechnologies.com/en-ae/documentation/unity-family/unity-p-replication- config/02-unity-rep-br-workflow.htm
NEW QUESTION 42
What is the minimum recommended amount of Flash capacity in a Dell EMC Unity 880 Hybrid pool?
- A. 5%
- B. 15%
- C. 10%
- D. 8%
Answer: A
Explanation:
Reference:
https://www.delltechnologies.com/en-us/collaterals/unauth/white-papers/products/storage/h15093- dell-emc-unity-best-practices-guide.pdf (16)
NEW QUESTION 43
What are the two biggest factors that determine IOPS when using SSDs in a Dell EMC SC Series array?
- A. Multi-tenant arrays and tier configuration
- B. Current latency and queue depth
- C. Read/write percentage and peak workload
- D. Application block size and overall throughput
Answer: D
Explanation:
Explanation/Reference: https://downloads.dell.com/manuals/common/sc-series-performance-availability-best-practices- dell-emc-4024-bp-sc_en-us.pdf
NEW QUESTION 44
When designing a Dell EMC SC Series system, which factors regarding general performance are important to understand?
- A. Block size and read size
- B. Latency and queue depth
- C. Transport and queue depth
- D. Write size and latency
Answer: B
NEW QUESTION 45
What are the two biggest factors that determine IOPS when using SSDs in a Dell EMC SC Series array?
- A. Multi-tenant arrays and tier configuration
- B. Current latency and queue depth
- C. Read/write percentage and peak workload
- D. Application block size and overall throughput
Answer: D
Explanation:
Reference:
https://downloads.dell.com/manuals/common/sc-series-performance-availability-best-practices-dell-emc-4024-bp-sc_en-us.pdf
NEW QUESTION 46
How many PCI-E lanes are provided for Slot 0 and Slot 1 in Dell EMC Unity XT arrays?
- A. 8 for Slot 0; 16 for Slot 1
- B. 16 for Slot 0; 16 for Slot 1
- C. 16 for Slot 0; 8 for Slot 1
- D. 8 for Slot 0; 8 for Slot 1
Answer: C
NEW QUESTION 47
What is the minimum recommended amount of Flash capacity in a Dell EMC Unity 880 Hybrid pool?
- A. 5%
- B. 15%
- C. 10%
- D. 8%
Answer: A
NEW QUESTION 48
......
DES-1D12 Exam Dumps - Free Demo & 365 Day Updates: https://prepaway.vcetorrent.com/DES-1D12-valid-vce-torrent.html